ZJHP Compact Pneumatic Single-Seat Control Valve

Product Details

Place of Origin: China

Brand Name: WEYO

Model Number: ZJHP

Payment & Shipping Terms

Minimum Order Quantity: Negotiable

Price: Based on oroiect reauirements

Packaging Details: Customized packaging to protect products

Delivery Time: 7 - 15 days for small orders, 15 - 30 days for large orders

Payment Terms: L/C, T/T

Supply Ability: 5000 units per month for small parts. 1000 units per month for large parts

Chat now
Highlight:

compact control valves

,

compact pressure reducing valve

,

pneumatic control valves

ZJHP Compact Pneumatic Single-Seat Control Valve
ZJHP Compact Pneumatic Single-Seat Control Valve
 
It is a new generation of control valve launched in the 1980s that complies with IEC standards, suitable for process control systems with various media fluids and process conditions.

 

In addition to the common advantages of pneumatic control valves, it also features reliable action performance, precise flow regulation, a large adjustable range, stable operation, and small leakage. It can achieve high-quality control effects in extensive applications across various industrial sectors.

 

Structural Principle:
The compact pneumatic single-seat control valve consists of a ZHA (B) type pneumatic multi-spring diaphragm actuator and a VJP type low-flow-resistance straight-through single-seat valve.

 

After the pneumatic signal pressure sent by the regulating instrument is input into the diaphragm chamber of the pneumatic diaphragm actuator, the push rod moves to drive the valve core, changing the opening cross-sectional area of the valve to achieve the purpose of regulating the medium flow. The stroke of the valve core has a corresponding proportional relationship with the input signal pressure.
 
Main technical indicators

Nominal diameter

DNmm
20 25 40 50 65 80 100 150 200
10 12 15 20 32 40 125 150

Rated flow coefficient

Linear

1.8 2.8 4.4 6.9 11 17.6 27.5 44 69 110 176 275 440 690

Equal percentage

1.6 2.5 4 6.3 10 16 25 40 63 100 160 250 400 630

Inherent flow characteristic

LinearEqual percentage

Inherent turndown ratio

50∶1

Nominal pressure (MPa)

0.6;1.6;4.0;6.4

Operating temperature (℃)

-20~200;-40~250;-40~450;-60~450

Ambient temperature (℃)

-40~85

Air supply pressure (MPa)

0.14;0.25;0.4

Model of matched actuator

ZHAB-22 ZHAB-23 ZHAB-34 ZHAB-45

Spring range (kPa)

Air-to-close

20~100;40~200;80~240

Air-to-open

20~100;40~200;80~240

Allowable pressure difference


MPa

Air-to-close type

20~100 0.14 6.4 6.19 3.96 2.23 1.43 0.87 0.56 0.35 0.34 0.22 0.14 0.15 0.1 0.06
20~100 0.25 6.4 6.4 6.4 6.4 6.4 5.68 3.64 2.3 2.21 1.43 0.91 0.95 0.66 0.37
40~200 0.4 6.4 6.4 6.4 6.4 6.4 6.4 5.04 3.18 3.06 1.98 1.26 1.32 0.92 0.52

Air-to-open type

20~100 0.14 4.64 3.09 1.98 1.11 0.71 0.44 0.28 0.18 0.17 0.11 0.07 0.07 0.05 0.03
40~200 0.25 6.4 6.4 5.94 3.34 2.14 1.31 0.84 0.53 0.51 0.33 0.21 0.22 0.15 0.09
80~240 0.4 6.4 6.4 6.4 6.4 4.99 3.05 1.95 1.25 1.18 0.78 0.5 0.51 0.36 0.21

 

Installation and Operation Notes:
● It should be installed vertically on horizontal pipelines. In special cases where horizontal or inclined installation is required, supports should generally be added.
● It should be installed close to the ground or floor slab for ease of maintenance and inspection. For those equipped with a valve positioner or handwheel mechanism, it is particularly important to ensure convenient observation, adjustment, and operation.
● A bypass pipeline is generally provided to switch to manual operation when the automatic control system fails or the control valve is being maintained, so as not to stop production.
● When equipped with a handwheel mechanism, the bypass pipeline can also be omitted for manual operation, and it can also be used to limit the opening of the valve. When not in use, the handwheel mechanism must be restored to its original neutral position to facilitate the normal operation of the automatic control system.
● During installation, the medium flow direction should be consistent with the direction indicated on the valve body.
● Before installing the control valve, the pipeline should be cleaned of dirt and welding slag. After installation, fully open the control valve, clean the pipeline and valve, and test the tightness of all connections.
 

Overall dimensions

Nominal diameter

L H H1 φA H2
PN16 PN40 PN64

Ordinary

High temperature

PN6 PN16 PN40 PN64
20 181 194 206 398.5 548.5 45 52.5 65 285 280
25 184 197 210 410.5 560.8 50 57.5 70 285 280
40 222 235 251 455 620 65 75 85 285 307
50 254 267 286 457.5 627.5 70 82.5 90
65 276 292 311 610 790 80 92.5 102.5 360 398
80 298 317 337 622 807 95 100 107.5
100 352 368 394 640 850 105 110 117.5
150 451 473 508 870 1130 132.5 142.5 150 172.5 470 530
200 600 600 650 890 1150 160 170 187.5 207.5
Note: The flange connection dimensions of this product are selected in accordance with the following standards:

 

  1. For a pressure of PN6, it is selected in accordance with GB216.3-84 Dimensions of Gray Cast Iron Pipe Flanges for 6 Bar.
  2. For a pressure of PN16, it is selected in accordance with GB4216.5-84 Dimensions of Gray Cast Iron Pipe Flanges for 16 Bar.
  3. For a pressure of PN40, it is selected in accordance with GB113.11-88 Integral Steel Pipe Flanges with Male and Female Faces for PN4.0MPa (40bar).
  4. For a pressure of PN64, it is selected in accordance with JB79-59 Cast Steel Flanges.

 

Ordering Information
  1. Product model
  2. Nominal pressure
  3. Nominal diameter
  4. Operating temperature
  5. Rated flow coefficient
  6. Inherent flow characteristic
  7. Action mode
  8. Spring range
  9. Materials of valve body and trim
  10. Accessories: Choose complete sets such as air filter pressure reducer, valve positioner (pneumatic, electrical), valve position switch, position retaining valve, handwheel mechanism, etc.