Product Details
Place of Origin: China
Brand Name: WEYO
Model Number: HPN
Payment & Shipping Terms
Minimum Order Quantity: Negotiable
Price: Based on oroiect reauirements
Packaging Details: Customized packaging to protect products
Delivery Time: 7 - 15 days for small orders, 15 - 30 days for large orders
Payment Terms: L/C, T/T
Supply Ability: 5000 units per month for small parts. 1000 units per month for large parts
Type:
|
Straight-through Cage-type Cast Globe Valve
|
Nominal Diameter:
|
40~200mm
|
Nominal Pressure:
|
ANSI 900, 1500, 2500; JIS 63K
|
Connection Type:
|
Flanged Connection: RF, RJ Standards: ANSI B 16.5; JIS B2201 Welded Type: Socket Weld (SW) (40~80mm); Butt Weld (BW) (80~200mm)
|
Materials:
|
ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 2.25Cr1.0Mo, 5.0Cr0.5Mo, SCPH21, SCPH32, SCPH61
|
Upper Valve Bonnet:
|
Normal Temperature Type (P): -5~+230℃ Extended Type Ⅰ (E1): +230~+566℃
|
Gland Type:
|
Bolt-clamped Type
|
Packing:
|
Asbestos Braided Packing
|
Type:
|
Straight-through Cage-type Cast Globe Valve
|
Nominal Diameter:
|
40~200mm
|
Nominal Pressure:
|
ANSI 900, 1500, 2500; JIS 63K
|
Connection Type:
|
Flanged Connection: RF, RJ Standards: ANSI B 16.5; JIS B2201 Welded Type: Socket Weld (SW) (40~80mm); Butt Weld (BW) (80~200mm)
|
Materials:
|
ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 2.25Cr1.0Mo, 5.0Cr0.5Mo, SCPH21, SCPH32, SCPH61
|
Upper Valve Bonnet:
|
Normal Temperature Type (P): -5~+230℃ Extended Type Ⅰ (E1): +230~+566℃
|
Gland Type:
|
Bolt-clamped Type
|
Packing:
|
Asbestos Braided Packing
|
Cv value and stroke are shown in Table 1. Table 1 | |||||||||||||||||||
Nominal diameter(mm) | 40 | 50 | 80 | 100 | 150 | 200 | |||||||||||||
Valve seat diameter(mm) | 25 | 32 | 40 | 32 | 40 | 50 | 50 | 65 | 80 | 65 | 80 | 100 | 100 | 125 | 150 | 125 | 150 | 200 | |
Rated Cv value | ANSI9001500 JIS63K |
8 | 12 | 20 | 12 | 20 | 30 | 30 | 43 | 62 | 43 | 62 | 90 | 90 | 135 | 210 | 135 | 210 | 330 |
ANSI2500 | - | 8 | 12 | 8 | 12 | 20 | 20 | 30 | 43 | 30 | 43 | 62 | 62 | 90 | 135 | 90 | 135 | 210 | |
Rated stroke(mm) | 25 | 38 | 50 |
75
|
Allowable Pressure Difference Ⅰ. Equipped with HA or VA actuator (with positioner) A. Air-to-close valve: See Table 2, Table 2 |
|||||||||
Nominal pressure | Actuator | Supply pressure (MPa) |
Spring range(MPa) | Allowable pressure difference(MPa) | |||||
Allowable pressure difference(mm) | |||||||||
40 | 50 | 80 | 100 | 150 | 200 | ||||
ANSI900 1500 JIS63K |
HA3D | 0.28 | 0.04-0.20 | 15.3 26.4 |
11.6 19 |
7.8 11.3 |
5.8 7.4 |
- | - |
0.3 | 15.3 26.4 |
11.6 24.8 |
7.8 15.2 |
5.8 10.3 |
- | - | |||
0.35 | 0.08-0.24 | 26.1 26.4 |
23.3 26.4 |
15.6 17.2 |
11.7 11.8 |
6.4 | - | ||
0.4 | 26.4 | 23.3 26.4 |
15.6 26.4 |
11.7 19.1 |
7.8 11.7 |
||||
HA4D | 0.28 | 0.04-0.20 | 21.1 26.4 |
20.1 26.4 |
13.5 22.7 |
10.1 15.9 |
6.7 9.1 |
5. 5.7 |
|
0.3 | 26.3 26.4 |
20.1 26.4 |
13.5 26.4 |
10.1 21 |
6.7 12.5 |
5 8.3 |
|||
0.35 | 0.08-0.24 | - | 26.4 | 26.4 | 20.2 23.5 |
13.5 14.2 |
9.5 | ||
0.4 | - | - | - | 20.2 26.4 |
13.5 22.6 |
10.1 15.8 |
|||
VA5D | 0.28 | 0.04-0.20 | - | - | - | 13.8 23.4 |
9.2 14.1 |
6.9 9.5 |
|
ANSI 2500 |
HA3D | 0.28 | 0.04-0.20 | 15.3 26.4 |
11.6 19 |
10.6 16.9 |
7.1 9.9 |
4.4 4.5 |
- |
0.3 | 15.3 33.9 |
11.6 24.8 |
10.6 22.2 |
7.1 13.5 |
4.4 6.7 |
- | |||
0.35 | 0.08-0.24 | 26.1 37.7 |
23.3 27.7 |
21.2 24.9 |
14.2 15.3 |
7.8 | - | ||
0.4 | 30.6 4.4 |
23.3 42.3 |
21.2 38.1 |
14.2 24.2 |
8.8 13.4 |
- | |||
HA4D | 0.28 | 0.04-0.20 | 21.1 44 |
20.1 35.9 |
18.3 32.4 |
12.3 20.3 |
7.6 11 |
6.7 9.1 |
|
0.3 | 26.3 44 |
20.1 44 |
18.3 41.5 |
12.3 26.5 |
7.6 14.8 |
6.7 12.5 |
|||
0.35 | 0.08-0.24 | 28.9 44 |
28.9 44 |
28.9 44 |
24.6 29.5 |
15.3 16.7 |
13.5 14.2 |
||
0.4 | 42 44 |
40.3 44 |
36.7 44 |
24.6 44 |
15.3 26.3 |
13.5 22.6 |
|||
HA5D | 0.28 | 0.04-0.20 | - | - | - | 16.8 29.4 |
10.4 16.6 |
9.2 14.1 |
|
1.The numbers in the dark boxes indicate the standard - specification actuators matched with the valve. 2.The condition for the allowable pressure difference when the valve is closed as shown in the table is △P = P1 (P2 = 0). The pressure difference when the valve is fully closed varies slightly with the outlet pressure P2. 3.The maximum allowable pressure difference shall not exceed the maximum value specified in ANSI B16.34 or JIS B2201. 4.The inlet pressure P1 shall not exceed the allowable pressure difference when the valve is closed. In the same cell, the upper value is the allowable pressure difference when the valve is fully open, and 5.the lower value is the allowable pressure difference when the valve is fully closed. |
B. Air-to-open valve: See Table 3, Table 3 | |||||||||
Nominal pressure | Actuator | Supply pressure (MPa) |
Spring range (MPa) |
Allowable pressure difference(MPa) | |||||
Nominal pressure(mm) | |||||||||
40 | 50 | 80 | 100 | 150 | 200 | ||||
ANSI900 1500 JIS63K |
HA3R | 0.28 | 0.08-0.24 | 15.3 26.4 |
11.6 19 |
7.8 11.3 |
5.8 7.4 |
- | - |
0.3 | 19 26.4 |
17.5 19 |
11.3 | 7.4 | - | - | |||
0.35 | - | 18.9 19 |
- | - | - | - | |||
HA4R | 0.28 | 21.1 26.4 |
20.1 26.4 |
13.5 22.7 |
10.1 15.9 |
6.7 9.1 |
5. 5.7 |
||
0.3 | - | 21 26.4 |
20.3 22.7 |
15.2 15.9 |
9.1 | 5.7 | |||
0.35 | - | - | 21 22.7 |
15.9 | - | - | |||
VA5R | 0.28 | - | - | - | 13.8 23.4 |
9.2 14.1 |
6.9 9.5 |
||
VA6R | 0.5 | 0.19-0.35 | - | - | - | 26.4 | - | - | |
0.5 | 0.19-0.40 | - | - | - | - | 19.1 26.4 |
- | ||
ANSI 2500 |
HA3R | 0.28 | 0.08-0.24 | 15.3 26.4 |
11.6 19 |
10.6 16.9 |
7.1 9.9 |
4.4 4.5 |
- |
0.3 | 19 26.4 |
17.5 19 |
15.9 16.9 |
9.9 | 4.4 4.5 |
- | |||
0.35 | - | 18.9 19 |
16.9 | - | - | - | |||
HA4R | 0.28 | 21.1 44 |
20.1 35.9 |
18.3 32.4 |
12.3 20.3 |
7.6 11 |
6.7 9.1 |
||
0.3 | - | 21 35.9 |
21 32.4 |
18.4 20.3 |
11 11 |
9.1 9.1 |
|||
0.35 | - | - | - | 20.3 20.3 |
- | - | |||
HA5R | 0.28 | - | - | - | 16.8 29.4 |
10.4 16.6 |
9.2 14.1 |
||
VA6R | 0.4 | 0.19-0.35 | - | - | - | 36.2 44 |
- | - | |
0.5 | 0.19-0.40 | - | - | - | - | 21.6 36.8 |
- | ||
1.The numbers in the dark boxes indicate the actuators specified in the standards that are matched with the valve. 2.The condition for the allowable pressure difference when the valve is closed as shown in the table is △P = P1 (P2 = 0). 3.The maximum allowable pressure difference shall not exceed the maximum value specified in ANSI B16.34 or JIS B2201. 4.The inlet pressure P1 shall not exceed the allowable pressure difference when the valve is closed. 5.In the same cell, the upper value is the allowable pressure difference when the valve is fully open, and the lower value is the allowable pressure difference when the valve is fully closed. |
Ⅰ. Equipped with VP actuator (with positioner): See Table 4, Table 4 | |||||
Nominal pressure | Actuator | Nominal diameter (mm) | Supply pressure (MPa) | ||
0.3 | 0.4 | 0.5 | |||
ANSI9001500JIS63K | VP5 | 150 | 19.8 24.2 |
26.4 | 26.4 |
ANSI2500 | 19.8 28.1 |
26.4 38.9 |
33 44 |
||
ANSI9001500JIS63K | VP6 | 200 | 19.1 26.4 |
25.5 26.4 |
26.4 |
ANSI2500 | 19.2 44 |
25.5 44 |
31.9 44 |
||
1.If the actuator is equipped with an auxiliary air supply, the smaller one of the two supply pressures shall be selected as the basis for calculating the allowable pressure difference. 2.The condition for the allowable pressure difference when the valve is closed as shown in the table is △P = P1 (P2 = 0). The pressure difference when the valve is fully closed varies slightly with the outlet pressure P2. 3.The maximum allowable pressure difference shall not exceed the maximum value specified in ANSI B16.34 or JIS B2201. 4.The inlet pressure P1 shall not exceed the allowable pressure difference when the valve is closed. 5.In the same cell, the upper pressure difference is the allowable pressure difference when the valve is fully open, and the lower pressure difference is the allowable pressure difference when the valve is fully closed. |
Equipped with HA,VA5,VA6,VP7 actuator
Flange distance: See Table 5. Table 5 Unit: mm |
|||||
Nominal pressure | Actuator | Nominal diameter(mm) | Supply pressure(MPa) | ||
0.3 | 0.4 | 0.5 | |||
ANSI9001500JIS63K | VP5 | 150 | 19.8 24.2 |
26.4 | 26.4 |
ANSI2500 | 19.8 28.1 |
26.4 38.9 |
33 44 |
||
ANSI9001500JIS63K | VP6 | 200 | 19.1 26.4 |
25.5 26.4 |
26.4 |
ANSI2500 | 19.2 44 |
25.5 44 |
31.9 44 |
Overall dimensions see Table 6 and Figure 2. Table 6 Unit: mm | ||||||||||||
Nominal diameter | Actuator | H | E | C | φB | |||||||
ANSI900 JIS63K |
ANSI1500 | ANSI2500 | ANSI 900 JIS 63K |
ANSI 1500 |
ANSI 2500 |
|||||||
P | E1 | P | E1 | P | E1 | |||||||
40 | HA3D,R | 735 | 875 | 735 | 875 | 780 | 725 | 100 | 105 | 115 | 363 | 350 |
HA4D,R | 890 | 1030 | 890 | 1030 | 935 | 1080 | 520 | 470 | ||||
50 | HA3D,R | 765 | 925 | 765 | 925 | 300 | 960 | 110 | 120 | 130 | 363 | 350 |
HA4D,R | 925 | 1085 | 925 | 1085 | 960 | 1120 | 520 | 470 | ||||
80 | HA3D,R | 800 | 980 | 800 | 980 | 835 | 1005 | 140 | 150 | 165 | 363 | 350 |
HA4D,R | 960 | 1140 | 960 | 1140 | 995 | 1165 | 520 | 470 | ||||
100 | HA3D,R | 835 | 1015 | 835 | 1015 | 880 | 1050 | 160 | 170 | 195 | 363 | 350 |
HA4D,R | 995 | 1175 | 995 | 1175 | 1040 | 1210 | 520 | 470 | ||||
VA5D | 1380 | 1560 | 1380 | 1560 | 1425 | 1595 | - | 620 | ||||
VA5R | 1490 | 1670 | 1490 | 1670 | 1535 | 1705 | - | 620 | ||||
VA6R | 1229 | 1409 | 1229 | 1409 | 1274 | 1444 | - | 445 | ||||
150 | HA3D,R | 895 | 1075 | 895 | 1075 | 935 | 1110 | 210 | 225 | 260 | 363 | 350 |
HA4D,R | 1055 | 1235 | 1055 | 1235 | 1095 | 1270 | 520 | 470 | ||||
VA5D | 1440 | 1620 | 1440 | 1620 | 1480 | 1655 | - | 620 | ||||
VA5R | 1550 | 1730 | 1550 | 1730 | 1590 | 1765 | - | 620 | ||||
VA6R | 1300 | 1480 | 1300 | 1480 | 1340 | 1515 | - | 445 | ||||
VP5 | 1080 | 1260 | 1080 | 1260 | 1120 | 1295 | - | 345 | ||||
200 | HA4D,R | 1155 | 1395 | 1155 | 1395 | 1185 | 1370 | 280 | 290 | 330 | 520 | 470 |
VA5D | 1545 | 1785 | 1545 | 1785 | 1575 | 1760 | - | 620 | ||||
VA5R | 1655 | 1895 | 1655 | 1895 | 1685 | 1870 | - | 620 | ||||
VP6 | 1395 | 1635 | 1395 | 1635 | 1425 | 1610 | - | 445 | ||||
1.P = normal temperature type upper valve bonnet; E1 = extended type Ⅰ upper valve bonnet. 2.The dimensions in column H of the table are the values when the control valve is not equipped with a handwheel mechanism. If it is equipped with a top-mounted handwheel mechanism, the dimensions of the handwheel mechanism shall be added accordingly. |
Weight see Table 7. Table 7 Unit: kg | |||||||||||||
公称 通径 (mm) |
执行 机构 |
法兰连接 | 焊接连接 | ||||||||||
ANSI900 JIS63K |
ANSI1500 | ANSI2500 | ANSI900 JIS63K |
ANSI1500 | ANSI2500 | ||||||||
P | E1 | P | E1 | P | E1 | P | E1 | P | E1 | P | E1 | ||
40 | HA3D,R | 60(55) | 65(60) | 65 | 70 | 90 | 95 | 50 | 55 | 55 | 60 | 75 | 80 |
HA4D,R | 90(85) | 95(90) | 95 | 100 | 125 | 130 | 80 | 85 | 85 | 90 | 105 | 110 | |
50 | HA3D,R | 70(65) | 80(75) | 75 | 85 | 110 | 120 | 55 | 65 | 60 | 70 | 85 | 95 |
HA4D,R | 100(95) | 110(105) | 105 | 115 | 140 | 150 | 85 | 95 | 90 | 100 | 115 | 125 | |
80 | HA3D,R | 105(100) | 115(110) | 140 | 160 | 225 | 245 | 85 | 95 | 110 | 130 | 170 | 190 |
HA4D,R | 135(130) | 145(140) | 170 | 190 | 255 | 275 | 115 | 125 | 140 | 160 | 200 | 220 | |
100 | HA3D,R | 135(125) | 160(150) | 195 | 225 | 315 | 345 | 105 | 130 | 155 | 185 | 230 | 260 |
HA4D,R | 165(155) | 190(180) | 225 | 255 | 345 | 375 | 135 | 160 | 185 | 215 | 260 | 290 | |
VA5D | 265(255) | 290(280) | 325 | 355 | 445 | 475 | 235 | 260 | 285 | 315 | 360 | 390 | |
VA5R | 290(280) | 315(305) | 350 | 380 | 470 | 500 | 260 | 285 | 310 | 340 | 385 | 415 | |
VA6R | 305(295) | 330(320) | 365 | 395 | 485 | 515 | 275 | 300 | 325 | 355 | 400 | 430 | |
150 | HA3D,R | 345(330) | 380(365) | 525 | 570 | 875 | 915 | 285 | 320 | 435 | 480 | 660 | 700 |
HA4D,R | 395(360) | 410(395) | 555 | 600 | 905 | 945 | 315 | 350 | 465 | 510 | 690 | 730 | |
VA5D | 475(460) | 510(495) | 655 | 700 | 1005 | 1045 | 415 | 450 | 565 | 610 | 790 | 830 | |
VA5R | 500(485) | 535(520) | 680 | 725 | 1030 | 1070 | 440 | 475 | 590 | 635 | 815 | 855 | |
VA6R | 515(500) | 550(535) | 695 | 740 | 1045 | 1085 | 455 | 490 | 605 | 650 | 830 | 870 | |
VP5 | 390(375) | 425(410) | 570 | 615 | 920 | 960 | 330 | 365 | 480 | 525 | 705 | 745 | |
200 | HA4D,R | 633(598) | 678(643) | 1065 | 1115 | 1500 | 1545 | 535 | 580 | 910 | 958 | 1193 | 1240 |
VA5D | 735(700) | 780(745) | 1165 | 1215 | 1600 | 1645 | 635 | 680 | 1010 | 1060 | 1295 | 1340 | |
VA5R | 760(725) | 805(770) | 1190 | 1240 | 1625 | 1670 | 660 | 705 | 1035 | 1085 | 1320 | 1365 | |
VP6 | 725(690) | 770(735) | 1155 | 1025 | 1590 | 1635 | 625 | 670 | 1000 | 1050 | 1285 | 1330 | |
Remarks: The numbers in parentheses indicate the weight of the valve with a nominal pressure of JIS 63K. |