WEYO AUTO TECH
flnn@bravowow.cn 86-13122669823-9-18
products
products
Home > products > Hydraulic Valve > HCU Unbalanced Cage Type Control Valve 40-200mm Nominal Diameter

HCU Unbalanced Cage Type Control Valve 40-200mm Nominal Diameter

Product Details

Place of Origin: China

Brand Name: WEYO

Model Number: HCU

Payment & Shipping Terms

Minimum Order Quantity: Negotiable

Price: Based on oroiect reauirements

Packaging Details: Customized packaging to protect products

Delivery Time: 7 - 15 days for small orders, 15 - 30 days for large orders

Payment Terms: L/C, T/T

Chat now
Highlight:

HCU Hydraulic Valve

,

200mm Hydraulic Valve

,

Unbalanced cage type control valve

Type:
Straight-through Single-seat Cast Globe Valve
Nominal Diameter:
40~200mm
Nominal Pressure:
ANSI 125, 150, 300, 600 JIS 10, 16, 20, 30, 40K PN 1.6, 4.0, 6.4MPa
Connection Type:
Flanged: FF, RF, RJ And LG Standards: ANSI B16.5, JIS B2201, JB/T79.1; PN1.6MPa, JB/T79.2 (male-female Face) Welded: Socket Weld (SW) (40~50mm); Butt Weld (BW) (65~200mm)
Materials:
HT200, ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 5.0Cr0.5Mo, SCPH21, SCPH61, Ti
Upper Valve Bonnet:
Normal Temperature Type (P): -17~+230℃ Extended Type I (E1): -45~-17℃, +230~+566℃ Extended Type II (E2): Integral Type (E2I): -100~-45℃; Welded Type (E2W): -196~-100℃
Gland Type:
Bolt-clamped Type
Packing:
V-type PTFE Packing, PTFE-impregnated Asbestos Packing, Asbestos Braided Packing
Type:
Straight-through Single-seat Cast Globe Valve
Nominal Diameter:
40~200mm
Nominal Pressure:
ANSI 125, 150, 300, 600 JIS 10, 16, 20, 30, 40K PN 1.6, 4.0, 6.4MPa
Connection Type:
Flanged: FF, RF, RJ And LG Standards: ANSI B16.5, JIS B2201, JB/T79.1; PN1.6MPa, JB/T79.2 (male-female Face) Welded: Socket Weld (SW) (40~50mm); Butt Weld (BW) (65~200mm)
Materials:
HT200, ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 5.0Cr0.5Mo, SCPH21, SCPH61, Ti
Upper Valve Bonnet:
Normal Temperature Type (P): -17~+230℃ Extended Type I (E1): -45~-17℃, +230~+566℃ Extended Type II (E2): Integral Type (E2I): -100~-45℃; Welded Type (E2W): -196~-100℃
Gland Type:
Bolt-clamped Type
Packing:
V-type PTFE Packing, PTFE-impregnated Asbestos Packing, Asbestos Braided Packing
HCU Unbalanced Cage Type Control Valve 40-200mm Nominal Diameter
HCU Unbalanced Cage-Type Control Valve
 
The HCU cage-type control valve is a single-seat sleeve-type control valve. The valve core has no pressure balance hole, and the valve body has a compact structure. The fluid channel is in an S-shaped streamline design, with a guide vane that improves the smooth flow of fluid around the sleeve, featuring small pressure drop loss, large flow rate, and a wide adjustable range. It is resistant to cavitation corrosion and has a high-precision flow characteristic curve.

The control valve has excellent closing tightness, with a valve seat leakage equivalent to that of a single-seat valve. It is equipped with a multi-spring diaphragm actuator, which has a compact structure and large output force. It can be widely used in occasions requiring low noise, little cavitation corrosion, and strict sealing performance.

Allowable pressure difference

I. Valves equipped with HA actuators are shown in Tables 2 and 3

A. Air-to-close valves Table 2

Actuator Supply pressure(MPa) Spring range
(MPa)
Positioner Allowable pressure difference(MPa)
Nominal diameter(mm)
40 50 65 80 100 150 200
HA2D 0.14 0.02~0.10 With or With out 0.34 0.2 - - - - -
0.4 0.08~0.24 With 0.68 0.4 - - - - -
HA3D 0.14 0.02~0.10 With or With out 0.61 0.36 0.26 0.18 0.1 0.05 -
0.4 0.08~0.24 With 1.22 0.72 0.52 0.36 0.2 0.1 -
HA4D 0.14 0.02~0.10 With or With out - - 0.45 0.31 0.18 0.09 0.06
0.4 0.08~0.24 With - - 0.9 0.62 0.36 0.18 0.12
VA5D 0.14 0.02~0.10 With or With out - - - - 0.24 0.12 0.08
0.4 0.08~0.24 With - - - - 0.48 0.24 0.16

 

B. Air-to-open valve Table 3

Actuator Supply pressure(MPa) Spring range
(MPa)
Positioner Allowable pressure difference(MPa)
Nominal diameter(mm)
40 50 65 80 100 150 200
HA2D 0.14 0.02~0.10 With or With out 0.34 0.2 - - - - -
0.4 0.08~0.24 With 0.68 0.4 - - - - -
HA3D 0.14 0.02~0.10 With or With out 0.61 0.36 0.26 0.18 0.1 0.05 -
0.4 0.08~0.24 With 1.22 0.72 0.52 0.36 0.2 0.1 -
HA4D 0.14 0.02~0.10 With or With out - - 0.45 0.31 0.18 0.09 0.06
0.4 0.08~0.24 With - - 0.9 0.62 0.36 0.18 0.12
VA5D 0.14 0.02~0.10 With or With out - - - - 0.24 0.12 0.08
0.4 0.08~0.24 With - - - - 0.48 0.24 0.16

Notes: 1. The numbers in the dark boxes indicate the standard specifications for valve actuators using Broussonetia papyrifera.
2. The maximum allowable pressure difference must not exceed the maximum values specified in ANSI B16.34 and JIS B2201.

 

Focal flange distance See Table 5 Table 5  Unit: mm

Nominal
Diameter

ANSI
125FF
150RF
JIS10K
FFRF
PN1.6
(MPa)
JIS
16K
RF
ANSI
300
JIS20K
30KRF
PN4.0
(MPa)
ANSI
600
JIS40K
RF
PN6.4
(MPa)
JIS
16K
LG
JIS
20K
LG
JIS
30K
LG
JIS
40K
LG
ANSI
150RJ
ANSI
300
RJ
ANSI
600RJ
ANSI
300
LG
ANSI
600
LG
ANSI
150
SW,BW
ANSI
300
600
SW,BW
40 222 231 235 251 235 236 248 251 235 248 251 244 248 251
50 254 263 267 286 265 267 276 286 267 283 289 276 283 286
65 276 288 292 311 290 292 303 311 289 308 314 302 308 311
80 298 313 317 337 310 317 326 337 311 333 340 327 333 337
100 352 364 368 394 360 368 379 394 365 384 397 378 391 394
150 451 465 473 508 475 473 486 508 464 489 511 483 505 473 508
200 543 560 568 610 570 568 580 610 556 584 613 578 606 568 610

 

HCU Unbalanced Cage Type Control Valve 40-200mm Nominal Diameter 0

HA                                VA5                              VA6                                    VP7

Allocate HA ,VA5,VA6,VP7execution machine broussonetia papyrifera

 

Ordering Information
  1. Model number
  2. Nominal diameter × valve seat diameter
  3. Nominal pressure and flange connection type
  4. Material of valve body and internal valve components, requirements for surface hardening treatment
  5. Type of upper valve bonnet
  6. Flow characteristic
  7. Actuator model, supply pressure
  8. Valve action type
  9. Accessories (positioner, handwheel, pressure reducing valve, etc.)
  10. Special requirements, such as oil-free, copper-free, etc.
  11. Medium name, temperature and specific gravity
  12. Normal flow rate and required maximum flow rate
  13. Medium pressure, inlet pressure and outlet pressure at maximum flow rate and minimum flow rate
  14. Medium viscosity and whether it contains suspension